VXDIAG VCX-FD Firmware Update Log

This post is about VXDIAG VCX-FD Firmware Update Log.

vxdiag-vcx-fd-firmware-update

Note: Please use the latest VX Manager for online firmware updates. If online updates are not possible, Please use VCX-FD offline update tool.

2024.04.24 —- V2.3.1.1
Optimization: Optimize CAN message send frame interval delay while waiting for sending to complete
Optimization: Optimize ISO15765 stmin and send continuous frame interval processing
Fix: Fix ISO15765 timer timing message to be independent of other messages and not affect others
Change: Change ISO15765 default p2max time to 10 ms
Changed: All protocol filters are enabled by default (no messages are received when no filter is configured)
Optimization: Low-level optimization: shell (user permissions)

2024.04.03 —- V2.3.0.2
Optimization: Refactor ISO9141, ISO14230, KW1281, KW82, and UART-based LIN
Optimization: Optimize the update of the P3MIN parameter of ISO14230 protocol (Toyota data flow interruption)
Optimization: Asynchronous execution with fast initialization/slow initialization (does not block other communication)
Optimization: Host communication commands can be executed asynchronously and concurrently
Fix: Forced sending of scheduled messages when ISO15765 protocol is idle
Fix: Filtering of J1850VPW protocol messages (corresponding to node address)
Optimization: Increase the buffer size of the telnet debug log
Optimization: Low-level optimization: shell, serial, timer, etc.

2024.01.09 —- V2.2.0.4
Modification: Processing of ISO15765 protocol flow control parameters (TX_STMIN)
Optimization: Increased transmission rate of ISO15765 protocol long frames (multi-task switching)
Optimization: Intelligent handling of firmware anomalies